AP2006 Mk2 Side Hinged
Door Operating Arm Kit
For the
automation of one pair of traditional barn type garage doors (opening
outwards)
FITTING
INSTRUCTIONS

1.
Close the doors and check that the lapping edges are not jamming and that
the doors are closing properly at the bottom
2.
Assemble the electric operator according to the manufacturers instructions
and reverse the motor & limit switch connections so that
the motor's safety reverse function operates during
door closure. (when trolley is moving towards motor)
3. Fix the
door header track bracket 20mm above the bottom edge and centrally on the
door header
4. Install
the electric operator according to the manufacturers instructions and
keeping the track horizontal.
5. Lay the AP2006 arms on the floor, swap the arms if necessary to suit door handing by
reversing the "L" arm (the hockey stick shaped bracket)
thus enabling the shortest arm
(with the larger spring) to be attached to the door that is rebated to
close first.
6. Make a
pencil mark at the top of both doors 1 mtr. from the hinged edge
7. Attach
the arms to the sliding trolley of the operator then fix the other ends of
arms to the doors at the 1 mtr. pencil mark.
(using 8mm x 40mm coachscrews)
Hint :- use a strap to support one arm while attaching the other arm to
the door
8. Lubricate
all moving & sliding parts with oil. (engine oil recommended)
9. Engage
and carefully run the electric operator and set the open & close limit
stop adjustments, the close limit stop should be set so as to allow
approx. 6mm of free travel when the doors are pushed out at the top by
hand.
Notes
:-
1/ Check the safety-stop system and make adjustments to the trip
sensitivity,
the motor must reverse if doors obstructed while closing (see step
2.)
2/ A cable
operated external release device should be fitted to enable manual
operation in the event of power failure if no
alternative access is available.
3/ All moving parts should be lubricated annually (engine oil recommended)
4/ To prevent loss & damage from forced entry our Securi-Dor bottom
locking kit model AP2007 Mk2 can be fitted to
automatically secure the doors at the bottom when closed.
Securi-Dor
AP2007 Mk2 Automatic Bottom Locking Upgrade
kit
adds Securi-Dor bottom locking to the AP2006 Mk2 side hinged barn door arm
kit
AP2007 Product details
AP2007 Fitting Instructions