AP2006 Mk2 Side Hinged Door Operating Arm Kit
For the automation of one pair of traditional barn type garage doors (opening outwards)

FITTING INSTRUCTIONS

1. Close the doors and check that the lapping edges are not jamming and that the doors are closing properly at the bottom

2. Assemble the electric operator according to the manufacturers instructions and reverse the motor & limit switch connections so that the motor's safety reverse function operates during door closure. (when trolley is moving towards motor)

3. Fix the door header track bracket 20mm above the bottom edge and centrally on the door header

4. Install the electric operator according to the manufacturers instructions and keeping the track horizontal.

5. Lay the AP2006 arms on the floor, swap the arms if necessary to suit door handing by reversing the "L" arm (the hockey stick shaped bracket)  thus enabling the shortest arm (with the larger spring) to be attached to the door that is rebated to close first.

6. Make a pencil mark at the top of both doors 1 mtr. from the hinged edge

7. Attach the arms to the sliding trolley of the operator then fix the other ends of arms to the doors at the 1 mtr. pencil mark.
(using 8mm x 40mm coachscrews)
Hint :- use a strap to support one arm while attaching the other arm to the door

8. Lubricate all moving & sliding parts with oil. (engine oil recommended)

9. Engage and carefully run the electric operator and set the open & close limit stop adjustments, the close limit stop should be set so as to allow approx. 6mm of free travel when the doors are pushed out at the top by hand.

Notes :-
1/ Check the safety-stop system and make adjustments to the trip sensitivity,
the motor must reverse if doors obstructed while closing (see step 2.)
2
/ A cable operated external release device should be fitted to enable manual operation in the event of power failure if no alternative access is available.
3/ All moving parts should be lubricated annually (engine oil recommended)
4/ To prevent loss & damage from forced entry our Securi-Dor bottom locking kit model AP2007 Mk2 can be
fitted to automatically secure the doors at the bottom when closed.

Securi-Dor AP2007 Mk2 Automatic Bottom Locking Upgrade kit
adds Securi-Dor bottom locking to the AP2006 Mk2 side hinged barn door arm kit